Fireproof Soild Core Wooden Door With UL 1.5 Hours

1. Minimum #10 x 1-1/2" long screws located a minimum 2" from the ends and 12" on center. 2. Maximum gap 1/4" gap between stud and back of wood frame. 3. PEMKO HSS 2000 listed and labeled intumescent fire-rated seal must be included in the door and frame system. 4. Minimum...

1.  Minimum #10 x 1-1/2" long screws located a minimum  2" from the ends and 12" on center.

2.  Maximum gap 1/4"  gap between stud and back of wood frame.

3.  PEMKO HSS 2000 listed and labeled intumescent fire-rated seal must be included in the door and frame system.

4.  Minimum casing is 1 -1/2" wide x 3/16" thick secured with minimum 1-1/2" finish nails a minimum 2" from the ends and  

    12" on center.

5.  Install all other fire rated hardware following the installation instructions provided with the hardware.

6.  Metal frame compare, and same match paiting.